How to Check Accuracy of Standard Weights Without a Calibration Lab

Standard weights are the foundation of all weighing and calibration processes. Whether you use them for laboratory balances, industrial scales, or precision instruments, their accuracy directly determines the reliability of your measurements. But what if you don’t have access to a calibration laboratory?


Don’t worry — in this expert guide, V-CARE IMPEX explains how to check accuracy of standard weights at your own facility using practical and reliable techniques.


Digital weighing scale with stainless steel standard weights placed on a wooden surface, illustrating how to check accuracy of standard weights without a calibration lab.

Understanding Standard Weights and Their Accuracy Classes

Before learning how to check accuracy of standard weights, it’s essential to understand what accuracy means in metrology. Standard weights are classified as per OIML R111 or E2, F1, F2, M1, M2, and M3 classes, each having specific tolerance limits.

  • E2 Class Weights – For ultra-high precision laboratories

  • F1 & F2 Class Weights – For general laboratory and industrial calibration

  • M1 Class Weights – For field and commercial scale testing

Each class has permissible tolerances in milligrams or parts per million (ppm). Exceeding these tolerances indicates that your weight may need re-calibration or replacement.


Simple Ways to Check Accuracy of Standard Weights Without a Calibration Lab

If you don’t have an NABL or ISO 17025 accredited calibration setup, you can still verify the condition of your weights using the following DIY verification methods:


1. Comparison with a Reference Weight

The most direct way to check accuracy of standard weights is by comparison.

Procedure:

  1. Obtain a higher-class or recently calibrated reference weight (for example, use an E2 weight to verify an F1).

  2. Place both weights alternately on a precision balance.

  3. Note the difference between the readings.

  4. If the difference is within the tolerance for that class (as per OIML R111), your weight is still accurate.

This method is called a substitution method and is commonly used for quick verification.


2. Use of a Precision Balance with Repeatability Test

If you own a high-accuracy analytical balance, you can test the consistency of your weight’s readings.

Steps:

  • Clean the weight and balance pan with a lint-free cloth.

  • Place the weight multiple times on the same spot.

  • Observe the repeatability (difference between highest and lowest readings).

  • If repeatability is poor, your weight may be damaged or magnetized.


3. Visual Inspection and Handling Check

Physical condition plays a vital role in the accuracy of weights.

Inspect for:

  • Scratches, dents, or corrosion

  • Faded markings or improper sealing

  • Fingerprints or dust accumulation (affects microgram precision)

  • Magnetic attraction (test using a non-magnetic tweezers)

Even a small dent or particle can shift weight values significantly, especially in E2 or F1 classes.


4. Magnetic Susceptibility Check

High-accuracy stainless steel weights (E2, F1) should have minimal magnetic properties. To check accuracy of standard weights for magnetism:

  • Bring a small magnet close to the weight.

  • If the weight attracts or repels, it may have magnetic contamination — affecting calibration results.

In such cases, the weight should be cleaned or replaced.


5. Temperature and Environmental Control

Weights can expand or contract with temperature changes. For consistent results:

  • Perform all checks at 20°C ± 2°C.

  • Avoid humidity or air drafts.

  • Allow weights to stabilize before testing.

These environmental precautions ensure repeatable accuracy even without a lab.


When to Send for Professional Calibration

Even if you regularly check accuracy of standard weights, professional NABL calibration is essential every 12 to 24 months, depending on:

  • Frequency of usage

  • Accuracy class

  • Working environment

If discrepancies exceed tolerance or your internal comparison shows drift, send them for re-certification to an accredited calibration lab.


Best Practices for Maintaining Accuracy

  • Handle weights using gloves or forceps only.

  • Store weights in wooden, ABS, or aluminium boxes to prevent contamination.

  • Keep them away from magnetic instruments and corrosive environments.

  • Label each weight with its last calibration date and next due date.

These habits help maintain the traceability and longevity of your standard weights.


Why Choose V-CARE IMPEX for Standard Weights

At V-CARE IMPEX, we manufacture and supply E2, F1, F2, and M1 Class Standard Weights in stainless steel and cast iron, certified by NABL-accredited labs. Our products meet OIML R111 and ISO 17025 standards, ensuring unmatched accuracy and durability.

We also provide re-calibration, verification, and storage solutions for laboratories, industries, and metrology institutions across India, UAE, Saudi Arabia, Singapore, and Qatar.


Conclusion

Knowing how to check accuracy of standard weights without a calibration lab empowers industries and labs to maintain measurement reliability between calibrations. By following the above methods — comparison, repeatability, and inspection — you can ensure your weights remain precise, compliant, and ready for use.

However, remember: these checks are verification steps, not substitutes for professional calibration. For guaranteed accuracy and certification, always trust V-CARE IMPEX, your dependable partner in calibration excellence.