How to Calibrate Analytical Balance – Complete Guide Using VCI PRECI Standard Weights
- darshan doshi
- 5 hours ago
- 3 min read
Analytical balances are essential for accuracy-critical applications in pharmaceutical labs, chemical research, food testing, academic institutions, and calibration facilities. Ensuring consistent accuracy requires routine calibration using certified weights. This comprehensive guide will explain How to Calibrate Analytical Balance properly, why calibration matters, and how VCI PRECI Standard Weights from V-CARE IMPEX guarantee the highest measurement reliability.

Why Calibration Is Important — Understanding How to Calibrate Analytical Balance
Analytical balances measure samples up to 0.0001 g (0.1 mg). Even a small environmental or mechanical disturbance can affect accuracy. Proper calibration:
Ensures traceability and compliance
Eliminates measurement drift
Ensures consistent accuracy
Prevents costly errors in formulation, analysis, and R&D
Meets audit and regulatory requirements (ISO, GMP, GLP)
To achieve this, high-quality calibration weights are mandatory.VCI PRECI Standard Weights (Class E2/F1) are ideal for analytical balance calibration due to their precision, durability, and global acceptance.
Types of Calibration for Analytical Balances
1. Internal Calibration (Automatic)
Some analytical balances have auto-calibration features. The balance uses an internal reference weight.
However, internal calibration SHOULD NOT replace external calibration.It is only a supporting function.
2. External Calibration (Using Standard Weights)
This is the gold standard and mandatory for:
Pharmaceutical labs
NABL/ISO labs
QC/QA departments
R&D facilities
Audit compliance
Using certified VCI PRECI E2 or F1 Class Standard Weights ensures traceable and accurate calibration.
Tools Required for How to Calibrate Analytical Balance
To perform accurate calibration, you need:
✔ VCI PRECI E2 / F1 Standard Weights (Highly Recommended)
Made with premium stainless steel and extremely low tolerance, VCI PRECI ensures stable, trustworthy calibration.
✔ Gloves or forceps (to avoid fingerprints)
✔ Clean calibration area
✔ Brush and lint-free cloth for dust removal
✔ Stable laboratory environment
Step-By-Step Guide: How to Calibrate Analytical Balance Using VCI PRECI Standard Weights
Step 1 – Stabilize the Environment
Before starting calibration:
Close all doors and windows
Turn off fans and air currents
Ensure balance is placed on vibration-free table
Keep temperature stable (20–25°C ideal)
Analytical balances are extremely sensitive, so environmental stability is crucial.
Step 2 – Warm Up the Balance
A balance must warm up for 30 minutes after switching ON.
This minimizes internal drift and ensures stable readings.
Step 3 – Clean the Balance Chamber
Use a soft brush or lint-free cloth.
Remove:
Dust
Chemical residues
Weighing paper particles
Cleanliness is essential for reliable results.
Step 4 – Select Correct VCI PRECI Standard Weights
For analytical balances (0.0001 g readability):
Use E2 Class weights for high-accuracy labs
Use F1 Class weights for routine labs
VCI PRECI E2/F1 Weights ensure compliance with:
ISO
NABL
OIML R111
GMP/GLP requirements
Step 5 – Perform External Calibration
Steps:
Press CAL / External Cal on the balance.
The display will show a required weight value (e.g., 100 g).
Pick the same VCI PRECI Standard Weight using forceps.
Gently place it at the center of the pan.
Wait for stability indicator.
Balance will accept the weight and adjust internally.
Remove weight when prompted.
Repeat with multiple weights (1 g, 10 g, 20 g, 50 g, 100 g) if required.
Step 6 – Perform Linearity Check
This confirms the balance is accurate across its entire range.
Use multiple VCI PRECI weights in sequence:
1 g
10 g
50 g
100 g
Check whether the display matches actual values.
If errors occur → recalibration or servicing is required.
Step 7 – Record Calibration Log
Maintain a documented calibration report including:
Date & Time
Weight Class Used
Weight Values
Errors Observed
Technicians’ initials
Calibration Certificate Number of VCI PRECI Weights
This improves audit compliance and traceability.
How Often Should You Calibrate Analytical Balance?
Recommended Frequency:
Daily external calibration
Weekly linearity check
After relocation of the balance
After any power fluctuations
Before critical experiments
Using VCI PRECI Standard Weights ensures consistency and reliability.
Benefits of Using VCI PRECI Standard Weights (By V-CARE IMPEX)
✔ OIML certified E2 & F1 class
✔ Mirror finish stainless steel construction
✔ Long-term stability
✔ NABL traceable certificates
✔ Perfect for analytical and microbalances
✔ Trusted by labs in India, Middle East & Asia
Your customers will trust your weight quality — making this blog an excellent tool to build credibility.
Common Mistakes to Avoid When Learning How to Calibrate Analytical Balance
Touching weights with bare hands
Calibrating in a room with unstable temperature
Using uncertified or cheap weights
Ignoring linearity testing
Skipping daily calibration
Performing calibration during heavy airflow
Using old or damaged weights
Using VCI PRECI Standard Weights eliminates most of these issues.
Conclusion – Mastering How to Calibrate Analytical Balance
Calibrating an analytical balance ensures precision, accuracy, and compliance in every weighing task. This educational guide shows How to Calibrate Analytical Balance correctly using VCI PRECI Standard Weights, ensuring trust, reliability, and long-term performance.
Whether you run a pharmaceutical lab, a calibration facility, a chemical R&D center, or an academic institution, precise calibration is non-negotiable.